Site Location
The plant owner Eco 2 Linc Ltd has decided to built a biomass fired renewable energy plant primary for the production of electricity.
The primary contractors of the plant is the consortium of BWE and BWSC, two independent companies situated in Denmark, just north of Copenhagen.
Overall project
The energy plant Sleaford is a new constructed renewable energy unit to be build in the UK. The plant is 100% biomass fired (natural gas is used for start-up), mostly straw, and produces approx. 40 MW electricity. The combustion technology is based on a water cooled vibration grate. See more on http://www.sleafordrep.co.uk
Straw is delivered as bales and the plant is able to receive Hesston bales, New Holland bales and Claas bales. Wood chips is used as auxiliary fuel.
The plant shall be designed for continuous operation at base load apart from one annual shutdown for repair, statutory inspection and repair
A centrally and fully equipped first aid facility will be located on the site.
Local/Site Conditions
The site is located just East of the town of Sleaford on the Boston road from the junction on A17.
ALL CARGO TRAFIC TO SITE MUST ARRIVE VIA THE A17 ROAD (SHOWN IN GREEN)
Use the GPS cordinates or simply type in the postal no NG34 9GH in the GPS
Sleaford is located approx. 50 km East of Nottingham and South of Newark on Trent

Site elevation:
|
12 m above sea level.
|
Normal annual plant operating time
|
approx. 7.500 hrs
|
Ambient temperature
|
-10 °C to +30 °C
|
Indoor temperature
|
+5 °C to +40 °C
|
Relative humidity
|
20% to 100%, average 60%
|
|
|
The plant will be optimised for the following normal conditions:
|
|
Indoor air temperature
|
+20 °C
|
Ambient temperature
|
+12 °C
|
Atmospheric pressure
|
1.013 mbar
|
Relative air humidity
|
85%
|
Wind data, direction and speed (m/s)
Ambient temperatures and humidity are in respective plant area
Location
|
Temperature range
|
Relative humidity
|
Outdoor
|
- 13 to 45 °C
|
F ≤ 100 %
|
Indoor turbine building, below turbine crane
|
0 to 45 °C
|
F ≤ 100 %
|
Turbine building at turbine crane level, floor illumination
|
55 °C
|
F ≤ 100 %
|
Indoor boiler house
|
60 °C
|
F ≤ 100 %
|
Fuel transfer area outside boiler house
|
- 13 to 45 °C
|
F ≤ 100 %
|
Switchgear and battery room. See NOTE
|
5 to 25 °C
|
F ≤ 90 %
|
Control room, electronic panel room. See NOTE
|
5 to 25 °C
|
F ≤ 90 %
|
NOTE: Equipment design temperature in control room and switchgear rooms is 40 °C
|
Satellite view of the site area

The GPS coordinates for the site is:
N 52° 59' 55" W 0° 22' 55"
or
52,998700° -0,381500°
Wind direction diagram

|